Articles

Rezoning vs Variance: Which Approval Does Your Project Need?

Who decides, under what legal test, and what each approval can and cannot do, with conditional uses and planned unit developments for comparison.

A variance and a rezoning both let an owner do something the zoning code does not currently allow. They are different tools, decided by different bodies under different tests, and asking for the wrong one is a common and costly mistake. The short version: a variance relieves one property from one rule because of a hardship; a rezoning changes the rules that apply to the property.

Worked in full in The Zoning and Entitlements Handbook by Julian R. Sterling, with every figure reproduced in live Excel workbooks.Get the DRM-free PDF, $19.99 →

The variance: relief from a standard

A variance is granted by a board of adjustment or zoning appeals. Its origin is the Standard State Zoning Enabling Act of 1926, which let a board vary the ordinance where literal enforcement would cause "unnecessary hardship," so that "the spirit of the ordinance shall be observed." Most states still use some version of that test.

In principle the applicant must show that the hardship comes from conditions peculiar to the property, such as its shape, slope or an unusual constraint, that it was not self-created, and that relief will not alter the essential character of the area. Many states apply a softer test to area variances (setbacks, height, coverage, parking) than to use variances, and some do not allow use variances at all.

The rezoning: a change of law

A rezoning, or map amendment, changes the district that applies to a property. It is adopted by the legislative body, usually after a planning commission recommendation, with public notice and hearings. The question is not hardship. It is whether the change is consistent with the comprehensive plan and serves the public interest. In many states neighbors can file a protest petition that raises the vote required; the model act set that threshold at owners of 20 percent of the affected area and a three-fourths vote.

Side by side

VarianceRezoning
Decided byBoard of adjustmentCouncil or other legislative body
Nature of the actQuasi-judicialLegislative in most states
TestHardship peculiar to the propertyConsistency with the plan, public interest
ScopeOne standard on one propertyAll rules of the new district
Typical useSetback, height, parking reliefA use or density the district does not allow
Main legal riskFindings not supported by evidenceSpot zoning, plan inconsistency, notice defects

Where conditional uses and PUDs fit

A conditional use permit approves a use that the district already lists as allowed subject to a hearing and criteria. The use is contemplated by the code; the location is judged. A planned unit development is a form of rezoning in which the developer proposes its own standards for the site, tied to a development plan, and the city negotiates them.

How to choose

  1. Is the use allowed in the district? If yes and only a dimension is off, look at administrative relief or an area variance. If it is listed as conditional, apply for the permit.
  2. Is the use not allowed at all? A variance is the wrong tool in most states. Boards that authorize a use the district does not contemplate risk reversal as an unlawful rezoning.
  3. Does an existing district fit the project? A conventional rezoning is simpler than a negotiated one.
  4. Does the project need its own standards? A PUD trades a more discretionary process for flexibility.
  5. Has the state already allowed it? Recent state housing laws in California, Texas, Florida and elsewhere allow some housing by right or through streamlined approval. Check before assuming any discretionary approval is needed.

A worked example

In the handbook case, Fenwick Yard is zoned I-1 Light Industrial, a district that lists no residential use. The developer wants 312 apartments. No variance can deliver that: there is no hardship peculiar to the parcel, and the change is one of policy. The existing mixed-use district would allow housing but with a height cap and parking ratio that yield roughly 276 units. The developer therefore seeks a PUD, at a density of 74.3 units per acre, paired with a development agreement. Two small dimensional issues found later are handled by administrative deviation inside the PUD, without a board hearing.

The choice has a price. The discretionary path is given an 80 percent chance at the council once it gets there, and a 53.5 percent chance of reaching a final approval overall. The handbook shows how to weigh that against the value the approval creates.

Common mistakes

Rules differ by state and city. This guide states common patterns and is not legal advice; local land use counsel decides which path applies.

Questions practitioners ask

What is the difference between a variance and a rezoning?

A variance is relief from a specific zoning standard for one property, granted by a board on a showing of hardship peculiar to that property. A rezoning changes the zoning district that applies to the property and is adopted by the legislative body as a matter of policy.

Can a variance change the allowed use of a property?

In many states, no, or only under a very strict test. A use the district does not allow normally requires a rezoning, a planned unit development or, if the code lists it as conditional, a conditional use permit.

Is a rezoning harder to get than a variance?

They are hard in different ways. A variance turns on a narrow legal test and the evidence in the record. A rezoning is a discretionary policy decision made in public, with hearings before two bodies in most cities and exposure to protest petitions and, in some places, referendum.

Read the full handbook

This guide is drawn from The Zoning and Entitlements Handbook, which follows Fenwick Yard from the first zoning memo and the option to the hearings, the final approval and the sale of the entitled site.

Paperback, $32.99 PDF edition, $19.99 Book page and companion workbooks

Free download: Entitlement Risk Budget (Excel).

Illustrative figures computed by the book model; Fenwick Yard is fictional. Education only, not legal, tax, engineering, or investment advice.