Articles

PJM capacity market: how ELCC accreditation and the VRR curve set clearing prices

How PJM Base Residual Auctions work: Forecast Pool Requirement, VRR Points A, B and C, marginal ELCC class ratings and administrative price collars.

Between the 2025/2026 and 2027/2028 delivery years, PJM Base Residual Auction clearing prices jumped from $269.92/MW-day to administrative price caps of $329.17 and $333.44/MW-day. Two mechanical levers drove that shift: marginal ELCC accreditation under FERC Docket No. ER24-99 and the steep upper slope of the Variable Resource Requirement (VRR) demand curve.

Worked in full in The Capacity Market Handbook by Julian R. Sterling, with every figure reproduced in a free 11-tab workbook.See the book →

Step 1: From 50/50 Peak Load to UCAP Reliability Requirement

Every PJM auction starts by converting a 50/50 coincident peak load forecast into an Unforced Capacity (UCAP) target using the Forecast Pool Requirement (FPR = (1 + IRM) x Pool-Wide Accreditation Factor). In our teaching case, a 152,000 MW peak load, a 17.8% Installed Reserve Margin and an 82.0% pool accreditation factor yield an FPR of 0.9660 and a System Reliability Requirement of 146,826 MW UCAP.

Step 2: VRR Curve Geometry and Administrative Collars

The piecewise VRR curve is anchored to Gross CONE ($634.15/MW-day UCAP) and Net CONE ($378.05/MW-day UCAP in our Base Case): Point A sits at 99.0 percent of reliability requirement (145,358 MW) at the greater of Gross CONE or 1.50 times Net CONE ($634.15/MW-day; PJM's Fifth Quadrennial Review raised the multiplier to 1.75x with Points B and C at 101.5% and 104.5% for 2026/2027+); Point B sits at 101.7 percent (149,322 MW) at $283.54/MW-day; Point C hits $0.00 at 106.8 percent (156,810 MW). Between Point B and Point A, the slope steepens to $88.44/MW-day per 1,000 MW of supply shift, which is why temporary caps ($333.44/MW-day cap, $179.55/MW-day floor) were adopted to bound consumer bill volatility.

Step 3: Marginal ELCC Ratings Cut Accredited UCAP

Under ER24-99 marginal ELCC rules, 2026/2027 PJM class ratings credited Nuclear at 95%, Gas CC at 74%, Demand Response at 72%, Gas CT at 60%, 4-hour BESS at 50% and Tracking Solar at 11%. Across Alderbrook Power Holdings' 740 MW nameplate fleet, marginal ELCC converts installed megawatts into 427.20 MW UCAP (57.73% weighted average). A 10-percentage-point ELCC drop on CCGT-1 and Bramwell BESS removes $6,055,350 of annual revenue at constant clearing prices.

Test your own asset in Excel

Download the free Capacity Market Calculator to convert ICAP to ELCC UCAP and model clearing prices, or explore the full 11-tab workbook in The Capacity Market Handbook.