How much heat a greenhouse uses and when, who pays for it, fuel price and weather sensitivity, energy curtains, fixed-price contracts, and backup.
Heating fuel is concentrated in the months a grower can least afford it. Here is how to measure it, cost it, cut it, and hedge it, worked on a fictional greenhouse.
Worked in full in The Greenhouse and Nursery Finance Handbook by Julian R. Sterling, with every figure reproduced in live Excel workbooks.Get the DRM-free PDF, $19.99 →
A field farm gets its heat from the sun; a northern greenhouse buys it. Heating fuel is concentrated in the months when the grower is already spending heavily on spring crops, it depends on the weather, and its price is set in energy markets. This guide measures the energy cost of the fictional Larkspur Hollow Greenhouses from The Greenhouse and Nursery Finance Handbook and works through three ways to change it. Fuel prices, use per square foot, and investment costs below are assumptions for illustration, not market data.
The model assumes Larkspur Hollow burns 2.40 therms of natural gas per covered square foot in a normal winter, 576,000 therms in all, at $0.80 per therm. Heating fuel costs $460,800 a year, and with electricity of $168,000, energy is $628,800, or 7.7% of net sales. The share looks modest. Its timing does not: 57% of the year's fuel is burned in January to March, when the houses are filling and the operating line is climbing.
| Month | Heating fuel |
|---|---|
| January | $101,376 |
| February | $92,160 |
| March | $69,120 |
| November | $46,080 |
| December | $59,904 |
Fictional case figures computed by the book's deterministic model.
Allocating each month's shared costs by the space each crop occupies that month puts the winter heat on the spring crops and the fall heat on the poinsettias, and very little on mums grown outdoors in summer. Spreading heat evenly over the year, or by sales, undercosts winter crops and can lead to the wrong crop mix decisions. For the full costing method, read how greenhouse economics work.
In the model, fuel twenty cents a therm dearer cuts EBITDA by $115,200 and raises the spring line peak to $2,501,335. A winter 15% colder than normal adds about $69,120 to the heating bill at the base price. Cold winters and high prices often come together, because regional cold lifts demand for gas, which is why the book's squeezed market state combines dear fuel with a bad spring.
An illustrative curtain project costing $1.10 per covered square foot, $264,000 in all, and cutting fuel use by 20%, saves $92,160 a year at the base price: a payback of 2.9 years and a positive net present value of $278,752 over 10 years at 11%. At the squeezed state's fuel price the saving rises to $120,960. Measure the saving against a normal winter, check its effect on light and humidity, and show the payback at more than one fuel price.
Fixing 70% of normal winter volume, 403,200 therms, at an assumed $0.85 per therm saves $80,640 if the market goes to the squeezed price of $1.05, costs $80,640 if it falls to $0.65, and costs $20,160 at the base price. The contract does not reduce the expected cost of fuel; it reduces the variance in the months when the borrowing base is tightest. Never hedge more than realistic use. For procurement strategy in depth, see The Commercial Energy Procurement Handbook.
Fuel use per covered square foot means little until it is adjusted for the winter. Divide each winter's fuel use by its heating degree days to separate the weather from the houses, track it by house where meters allow, and compare fuel cost per unit of spring crop sold over several years. Watch electricity too: supplemental lighting for young plants adds load at the same time as the heating peak and can raise demand charges. Every efficiency investment, from curtains to boiler upgrades to lighting, should be judged against a normal-winter baseline and at more than one energy price, because a project that pays back in three years when fuel is dear may take five when it is cheap.
Finally, put energy into the winter cash plan month by month, at the expected price and at a stress price, with the share already fixed by contract shown separately. That is the view a lender needs in February.
The worst energy event is not a price spike but a night without heat. In the book's case, a heating failure at the end of March destroys 15% of the spring annuals and baskets still on the benches and costs $613,837 of EBITDA before insurance. Backup heat, generators, and alarms that reach more than one person are worth more than their cost suggests. To test fuel price and a bad spring on your own figures, use the free Greenhouse Crop Model (Excel).
In the coldest months. In the book's fictional case, more than half of the year's heating fuel is burned from January to March, when spring crops fill the houses.
Often, but the payback depends on the fuel price, the winter, and the baseline. Test it at more than one fuel price and check its effect on light and humidity.
A fixed-price contract reduces variance, not the expected cost. It is most useful when the spring borrowing base is tight. Never hedge more than realistic use.
This guide is drawn from The Greenhouse and Nursery Finance Handbook, which follows a fictional family greenhouse through its year, its crop costs, energy, labor, insurance, credit, debt, and value, with a container nursery and an expansion alongside.
Paperback, $32.99 PDF edition, $19.99 Book page and companion workbooks
Free download: Greenhouse Crop Model (Excel).