Articles

PJM Capacity Performance penalties: a worked PAI non-performance charge example

Step-by-step PJM Capacity Performance calculation: hourly and 5-minute NPCR from Net CONE, Balancing Ratio, stop-loss caps and portfolio netting.

Under PJM Capacity Performance, failing to deliver power during a five-minute Performance Assessment Interval (PAI) can cost more in a single winter weekend than a generator earns all year. On a UCAP Net CONE of $378.05/MW-day, the hourly Non-Performance Charge Rate reaches $4,599.59/MWh ($383.30 per MW per five-minute interval).

Worked in full in The Capacity Market Handbook by Julian R. Sterling, with every figure reproduced in a free 11-tab workbook.See the book →

Deriving the Non-Performance Charge Rate (NPCR)

PJM anchors the penalty rate to Net CONE over 30 assumed emergency hours per delivery year: Hourly NPCR = (Net CONE_UCAP x 365) / 30 = ($378.04878 x 365) / 30 = $4,599.59/MWh (using unrounded $310.00 / 0.8200 = $378.04878/MW-day UCAP). Following FERC Order No. 825, settlement occurs every five minutes (12 intervals per hour), setting the interval charge rate at $383.30/MW-interval. Under FERC Docket No. ER24-99 (effective 2025/2026+), monthly and annual stop-loss caps are indexed to the Base Residual Auction clearing price (0.5x monthly / 1.5x annual). During each PAI, Expected Performance equals Committed UCAP multiplied by the Balancing Ratio (85.0 percent in our winter cold snap).

Worked 18-Hour Cold Snap Settlement

AssetUCAP (MW)Capped PenaltyBonus PayNet PAI
Alderbrook CCGT-1 (6-hr outage)236.80$5,554,837$1,709,724-$3,845,113
Kestrel Peaker CT-2 (dual-fuel)84.00$0$2,556,638$2,556,638
Redstone Solar (monthly cap hit)13.20$674,520$0-$674,520
Bramwell BESS (4-hr depleted)50.00$2,736,758$551,951-$2,184,807
Harborview DR Portfolio43.20$0$747,121$747,121
Standalone SPV Total427.20$8,966,115$5,565,435-$3,400,681

Why Within-Portfolio Netting Saves $457,530

When bonus pools experience 20 percent dilution (paying $3,679.67/MWh against $4,599.59/MWh in penalties), settling assets separately loses $919.92/MWh on offsetting positions. Netting all five Alderbrook assets inside a single account reduces net PAI losses from -$3,400,681 to -$2,943,151, saving $457,530 in a single storm and preserving $54,568,439 in net annual capacity revenue.

Stress-test your own winter PAI exposure

Download the free Capacity Market Calculator in Excel to model PAI shortfalls and stop-loss caps, or get the full 11-tab workbook in The Capacity Market Handbook.